Advantages and Highlights:
Leakage testing: Can test hydrogen, air, and water three channels simultaneously, and can conduct cross, external, and total leakage tests.
Compatible with flow method and differential pressure method, external leakage pressure adjustable from 0 to 300 kPa,串漏 pressure adjustable from 0 to 50 kPa.
The airtightness testing equipment is equipped with quick connectors for rapid water, hydrogen, and air interface connections.
Flow control accuracy: ±(0.8%RD + 0.2%FS), range is 0.01~500 sccm, display accuracy: 0.01 ml
Pressure display accuracy: 0.1kPa, detection pressure range: 0~300kPa
Equipped with a host computer, parameters, current status, and test results can all be displayed and uploaded to the MES system.
Equipped with insulation resistance testers, mobile multifunctional airtightness testing platform, test data can be uploaded to the MES system.
Provide electrical inspection 12 and 24VDC power supply
The height of the test platform meets ergonomic standards.
Equipped with standard leakage hole branch, it can calibrate the flowmeter.
The airtightness test has a self-checking procedure and can perform regular self-checks.